Infection Control Measures to Take During Hospital Construction and Renovation Projects

!: Infection Control Measures to Take During Hospital Construction and Renovation Projects

Hospital renovations can be one of the most challenging areas of construction and should only be done by experienced professionals. Owners should always request the contractor's health and safety plan and have an (ICRA) Infection Control Risk Assessment created prior to work commencing. It is as important for the owner's representative as well as the contractor to be aware and implement these Infection Control Measures to reduce the facilities risk of spreading or creating infections from construction activities. People are in the hospital to get better not be exposed to situations in which they could get worse.

1. Containment Areas. Properly blocking off and barricading work spaces is one of the most important measures taken during a hospital renovation. The contractor should utilize floor to deck temporary wall partitions to fully seal off an area that will be undergoing construction activities. Typically, thick plastic barriers with zippered doors can be utilized on small projects / short duration projects. While on larger areas, temporary walls constructed of metal framing and gypsum drywall are more practical. In long term projects the metal frame and drywall option will be more durable. Typically the contractor will place 2 doors in these temporary wall partitions for compliance with 2 means of egress. Utilizing barriers constructed of gypsum wallboard, metal studs, and standard interior doors will provide the contractor a space that can be secured when the jobsite is down which will limit risks of theft and injuries. Containing the construction is important for safety of workers / patients wandering into construction areas as well as to prevent dust from spreading into the hospital.

2. Negative Air Pressure. In most cases, when performing construction activities the contractor will be generating dust. For the safety of the hospital and patients the contractor wants to create negative pressure air so that the space under construction is actually pulling air from the hospital instead of pushing air into the hospital. These negative air machines contain HEPA filters and will actually filter the air and are routed to the outside of the hospital through an exhaust duct via a window. The size of the machine to be selected and used will be based on the size of the space and CFM required. Many brands exist and a local abatement supply store is often a good place to find these. Rental stores may carry these as well. The best advice is to compare the HEPA replacement filter pricing as these can be expensive and required frequent changing depending on the size of the space to be renovated and types of dust generating activities to be performed. The one caveat to this is certain areas of the hospital are sterile processing areas and are required to be under Positive are pressure. These areas are the exception to the rule and should not be placed under negative air pressure. 3. Closing off Return and Supply Air Vents. Another important measure in control infections in hospital construction is to isolate the renovation space from the main building's HVAC system. All return air vents should be closed, taped, or blocked off as to keep any dust generated in the construction zone from being circulated and entering the rest of the hospital. All supply vents should be disconnected as well, if possible. This will help with the negative air pressure of the space and keep the dust contained to the area of construction. This is a measure that requires a common sense approach. In some regions, extreme cold and hot weather may not allow for disconnecting of the supply vents because of freezing / overheating risks. These risks are understandable and can be overcome with a larger negative air machine to offset the supply CFM entering the space.

4. Dust Control. Another good practice for preventing dust from spreading into the floor areas of the hospital is to keep a clean jobsite. Utilize HEPA Filtered Shop Vacuums; they filter most of the air particulates to keep down the dust. Also, Dry Mop the area at mid day and end of business and follow that with a wet mop depending on the construction activities ongoing. This will keep the floors clean and minimize dust / debris on workers shoes and the chance of tracking that through the hospital. At the construction entrances utilize a dry mop, wet mop, and walk off mats. Require workers to wipe their feet on a dry mop then a wet mop, and then a sticky mat prior to exiting the space. These mats have a sticky side that the workers and roll carts pass over on the way in and out of the space and it pulls dirt and debris into the mat. Depending on construction activities going on in the space these mops and mats require more or less frequent changing and attention. The best entrance / exit of a space would be through stair wells in most cases. This helps to minimize tracking dirt throughout the entire hospital and also to limit the steady stream of workers from going in and out all day possibly disrupting day to day hospital activities.

5. Trash / Debris Removal. The best practice for removing debris from a workspace is to utilize a trash chute from a window for example that leads directly to a dumpster. Any debris going down the chute should be kept wet in order to minimize dust. Minimizing dust from the debris will keep the outside air vents of the buildings taking the air back in the hospital. If this option is not available covered rolling dumpsters should be utilized. By utilizing these covered dumpsters it will help to prevent any dust coming off the debris as it is wheeled through the hospital on its way to the outside disposal location. If you are a Hospital Representative in need of a contractor for a hospital construction project...

Give us a call. We'll be glad to give you an estimate on your project, produce a construction schedule, and layout an Infection Control Plan to minimize risk to your site.


Infection Control Measures to Take During Hospital Construction and Renovation Projects

Cheap Freeze Dry Meals Roland Drum Kits Ideas Swimming Pool Chlorinators Coupon

Thursday, December 15, 2011

Sportsman GEN154 2,000 Watt 80cc 4-Stroke Portable Generator

!: Saved Sportsman GEN154 2,000 Watt 80cc 4-Stroke Portable Generator quickly

Brand : Buffalo
Rate :
Price : $199.00
Post Date : Dec 15, 2011 15:54:56
Usually ships in 24 hours



Ideal for camping trips or as a backup power source at home, the Buffalo Tools 2,000-watt portable gas generator features a 4-stroke, 80 cc engine for easy starts. It has an automatic low-oil shutoff mode to prevent engine damage, and with a 1.32-gallon fuel tank, the unit will run 9-hours at a 50-percent load. The generator is EPA approved, and comes backed with a 90-day warranty.

Interview Kids Guitar Electric Discounted Mizuno Baseball Gloves

Friday, November 25, 2011

All Power America APG3201 6,500 Watt 10 HP Diesel Powered Generator With Electric Start & Wheel Kit

!: Good bargain All Power America APG3201 6,500 Watt 10 HP Diesel Powered Generator With Electric Start & Wheel Kit Immediately

Brand : All Power America | Rate : | Price : $1,249.99
Post Date : Nov 25, 2011 19:04:20 | Usually ships in 24 hours


  • 6,500 Watts Surge/5,000 Watts Continuous
  • 10 HP 4-Stroke Engine
  • Runs 8 hours at 50% load
  • Volt and hour meters
  • Non-CARB Compliant/Not For Sale In California

More Specification..!!

All Power America APG3201 6,500 Watt 10 HP Diesel Powered Generator With Electric Start & Wheel Kit

Shop Stihl Electric Blower Purchasing Peanut Butter Fudge Recipe Remington 16 Electric Chain Saw Life Tips

Wednesday, November 23, 2011

Diesel Generator - Models

!: Diesel Generator - Models

Nowadays the companies are producing diesel generators that do not create loud sounds at all. Moreover they are very light devices. These brilliant improvisations of sound level and decreased weight have caught the eye of people. That is the reason why people tend to purchase these generators because they have more features as compared to other devices. They are available in the market in different models. Given below I have provided some information on the Onan Pro Series model and the Red Hawk model.

The specialty of Onan generator is that their wattage level is ranging from 3000 to 6000 watts. These amazing devices run for hours and hours. Moreover their performance is brilliant whenever the power is required. The Onan generator is not at all heavy weight and they are simple to utilize in conditions where you have to use them in remote areas. They have a big diesel container that is why they run for a long time. When the fuel level is down, these devices stop working automatically.

Red Hawk generators are available in diverse types that offer different energy levels. You can utilize these generators for your house or if you are planning to go for camping then these devices are useful for you because of their portability factor. These devices have got a system that has 12 horse power. Moreover, the Red Hawk diesel generator is also a very quiet generator.

Both of these models offer dependable diesel power. After the introduction of low level sound diesel generators which are light weight, consumers really want to utilize these devices. Moreover the durability of these devices has also been enhanced. Electric generators are the main competitors of the diesel generators as both of them provide many benefits for the customers. The new innovations in the diesel generators are really making them prominent.


Diesel Generator - Models

Comment Charge Controller Solar Panels Keen Saratoga Shoes Save You Money

Monday, November 21, 2011

Marine Diesel Engines

!: Marine Diesel Engines

There isn't much an amateur mechanic with a limited tool kit can (or should) do to the major components inside marine diesels apart from making sure that it has a good supply of fuel and air and clean lubricating oil.

You can, however, check and adjust the gap between the rocker and the valve. There has to be a gap - usually about the thickness of a fingernail - to allow for the different rates at which the various components expand and contract as they warm up. Without it, there's a very real risk that the valves won't shut completely: they may even come into catastrophic contact with the pistons. If the gap is too large, the valves may not open as far as they should, and the engine will certainly be noisier than it should be.

1 Read the engine manual to find out what the valve/rocker clearances should be, and whether they should be adjusted with the engine cold or at normal running temperature. Note that the clearances for inlet valves may be different for those for exhaust valves, because exhaust valves get hotter.

2 Remove the rocker cover - a relatively thin metal box on top of the engine, usually with the oil filler cap in the middle. Some engines have a separate rocker cover for each cylinder, or for each of two or three groups of cylinders.

3 Check the gap on each valve in turn, when the valve is completely closed and the gap is

its widest. There are two ways of finding out when this happens. On a multi-cylinder engine, the best way is to find the 'magic number' for your engine by adding one to the number of cylinders. For a four-cylinder engine, for instance, the magic number is five.

4 Turn the engine slowly by hand , if necessary using a spanner on the crankshaft (big nut on the lowest of the pulleys at the front of the engine). Watch the rockers moving as you do so, until the two rockers for one cylinder are 'on the rock' - that is, when one is rising and the other falling - signifying that this particular cylinder is at the end of its exhaust stroke and just beginning its induction stroke. Subtract the number of this cylinder from the 'magic number' to find the number of the cylinder that is ready to have its valve clearances checked. If, for instance, you have a four-cylinder engine and number 2 cylinder's valves are on the rock, number 3 cylinder is ready, because 5 - 2 = 3.

5 On a single-cylinder engine, the clearance for one valve should be checked when the other valve is fully depressed. You can use this approach for a multi-cylinder engine, but it will take longer!

6 Slacken the lock-nut on the rocker whose clearance you are about to adjust, and then unscrew the threaded adjuster about one or two turns.

7 Set a feeler gauge to the clearance specified in the engine manual, and slip it between the valve stem and the rocker. Gently wiggle the feeler gauge whilst tightening the adjusting screw, until you can feel the feeler gauge being nipped between the valve stem and the rocker.

8 Leave the feeler gauge in place, and hold the adjusting screw with a screwdriver while you tighten the lock-nut. When it's tight, wiggle the feeler gauge again to check that you haven't upset the adjustment: you should feel a slight resistance, but it shouldn't be jammed tight.

9 Repeat the process for each valve in turn, then replace the rocker cover, making sure that the cork or rubber sealing gasket is smooth, undamaged and properly seated.


Marine Diesel Engines

Michael Kors Layton Handbag For Sale Philips Ambisound For Sale Ukf8001 Pur Best

Tuesday, November 15, 2011

Private Solar Powered Generator - Off-The-Grid Emergency Backup Power!

!: Private Solar Powered Generator - Off-The-Grid Emergency Backup Power!

Sooner or later most of us will face a natural disaster and or extended loss of electrical power. Recent Head Line news featuring Earthquakes and Snow and Ice storms highlight the devastating effect extended power outages inflict on human populations.

Having an emergency backup system is becoming a necessity. A newly arrived departure from conventional gas or diesel generators is a simple no fuss Easy to Use Solar Powered Generator. A reliable backup power source would alleviate much needless suffering by guaranteeing use of Essential Appliances during Emergency Situations.

A few hours without power is manageable, however days or weeks without power can have serious consequences! Think about this - the sun is FREE. The sun can produce an endless supply of electricity providing "On Demand" power prior to, during and after emergency situations.

Having a private Solar Powered Generator can provide up to twelve hours of uninterrupted backup power. Until now backup power products on the market have only been able to provide limited backup power for electrical outages. Extended run times are now available!

New Generation Privately Owned Solar Powered Generators are able to perform the following benefits:

Maximum power in minimum time: The ease of setting up a New Generation Solar backup system has been reduced to MINUTES. Plug in appliances and you are good to go! Run AC and DC appliances anywhere and anytime you need power.

Portable Power: If you have to leave your home for any reason, place the Solar Generator in your car and go!

Multiple Uses: Aside from Essential Appliances, a solar generator will recharge phones, run shortwave radios, televisions, lights, computers and printers. It will work in the woods at your cabin, tent camping or in a boat. It runs power tools, coffee makers or whatever you need.

Generates Permanent Power: Store power and have it available when you need it. Many users choose to keep appliances plugged in permanently to substantially reduce monthly electrical costs.


Private Solar Powered Generator - Off-The-Grid Emergency Backup Power!

Circulating Water Pump Order

Tuesday, November 8, 2011

EPA Issues New Rules Under the Clean Air Act on Emissions

!: EPA Issues New Rules Under the Clean Air Act on Emissions

Earlier this year, the Environmental Protection Agency (EPA) issued new rules under the Clean Air Act on toxic emissions and in particular, the emission of pollutants by diesel-powered, internal combustion engines. Reciprocating Internal Combustion Engines (RICE) are also known as "compression engines", are the target of this legislation and they are used very widely across the country to generate electricity, for use in power generation plants, industrial facilities, chemical plants and refineries as well as many manufacturing installations. RICE installations are also used to provide emergency back-up power for use by emergency services and for flood prevention and management.

The new rules mean that practically, all engine and associated pump and compressor equipment will require the installation of pollution control measures, and be subjected to additional checks and monitoring procedures. In some instances, engines will be required to burn ultra-low sulfur fuels.

The pollutants which the EPA rules are targeting include carbon monoxide (the primary pollutant which the EPA is seeking to reduce and control). Carbon monoxide has been found by the EPA to be associated closely with pollution by a wide variety of toxic emissions, including but not limited to benzene, formaldehyde, toluene, styrene, naphthalene and many others (primarily organic compounds in nature).

Other toxic pollutants not directly covered by the new rules are also expected to be reduced by the measures being introduced, including the emission of nickel, mercury, selenium, chromium, cadmium, manganese and in particular the emission of sulfur oxides.

The new EPA rules deals with only existing static installations and sub-divides RICE engines into "major" and "area" sources. A major source is any static pollutant source with actual or potential emissions in the range of 10 tons per year or of a single regulated pollutant, or; has the potential or is actually emitting 25 tons or more of any combination of regulated pollutants.

If a static ICE installation does not qualify as a major source it is designated as an area source.

There are several sub-classifications of based on emission limits of both major and area sources and which is based upon engine horsepower.

Engine start-up s may involve the emission of pollutants in excess of the mandated EPA limits, and to accommodate the new limits, the EPA rules only allow for engine start-ups to exceed more than 30 minutes. There are exceptions to this rule.

The new EPA rules also require changes to maintenance schedules, in particular the changes of lubricants and filters as well as certifying inspection of air hoses, belts and cleaners all within specified time periods. A key pillar of the new rules is the need for operators to demonstrate compliance with the new rules.

In summary, the new rules impact all existing, static RICE installations. Ancillary equipment such as pumping equipment will also be affected. Operators using RICE facilities to generate electricity are most affected. There is a comprehensive need to comply with the new rules in fact but also to demonstrate compliance which means improving or establishing documentation procedures as well as establishing appropriate maintenance and inspection scheduling.


EPA Issues New Rules Under the Clean Air Act on Emissions

Saved Silent Piano Commercial Loan Broker Tips Liver

Wednesday, October 26, 2011

Diesel Generator Handbook

!: Purchasing Diesel Generator Handbook buy

Brand : | Rate : | Price : $317.22
Post Date : Oct 26, 2011 14:12:11 | Temporarily out of stock. Order now and we'll deliver when available. We'll e-mail you with an estimated delivery date as soon as we have more information. Your credit card will not be charged until we ship the item.


Diesel Generator Handbook meets the need for an authoritative reference work covering the range of mechanical and electrical topics embodied in the practical design and application of diesel generating plant. It will be particularly welcomed in many parts of the developing world where the diesel generator is basic to the electricity supply system.





The discussion covers, in fifteen chapters, the prime mover, power ratings, synchronous generators, load assessment, control principles and systems, switchgear and controlgear, standby power, fuels and lubricating oilss, installation and commissioning, noise reduction, and plant operation and maintenance.

The book thus caters for all who are concerned with the selection, specification, testing, commissioning, operation and maintenance of diesel-based generator systems: not only the practising plant or services engineers, but also non-specialist engineers and users. The young technician or trainee engineer who is embarking on a career in the supply industry will find this handbook an invaluable investment.

L L J Mahon, FIEE, FBIM, after an engineering apprenticeship with BTH in Rugby, gained over 30 years' experience in the design, development, manufacture, installation and commissioning of both stationary and highly specialised mobile diesel generator plant for a range of applications.

An informative reference work covering the range of mechanical and electrical topics within the practical design and application of diesel generating plants
Ideal for professionals concerned with diesel-based generator systems
An invaluable source of information for the your technician or trainee engineer starting a career in the supply industry

More Specification..!!

Diesel Generator Handbook

Classic Winnie The Pooh Baby Bedding Ideas Promo Frye Boots Atlanta Saving Electric Reel Lawn Mower

Friday, October 21, 2011

Diesel Generators - What You Need To Know

!: Diesel Generators - What You Need To Know

If you are looking for a standby source of emergency power should a power outage occur or if you are simply looking for a prime source of energy, then generators are the answer.

There are many different types of fuel powered generators available. Diesel generators are among them. Diesel generators are the least flammable of all generators, have a longer life, and only take a small amount of maintenance. Diesel generators are also easily obtainable and have good fuel consumption. The average diesel generator will run 20,000 hours before needing service, and since they have no carburetors, you will never need to replace spark plugs.

You will find there are many brand names to choose from when searching for a diesel generator. Among them are Generator Joe, Honda, Daewoo, John Deere, Kohler, Cummins, Generac, Volvo, MQ Power and Norpro. These are all reliable names in the generator world. The generator you choose will depend mostly upon your needs. This is why before you make your purchase, it is important to know what features are available and which ones are most important to you.

When purchasing a major item like a diesel generator, it is vital to know what is out there. It is important to consider whether you need the generator as a standby or primary source of power. Some diesel generators are portable, while others are stationary. Diesel generators will have either single or three-phase power. Single-phase power is intended for uses under 5hp, which is best suited for a homeowner. Three-phase power is suited more for industrial or commercial users and is good for running motors. As you can probably see, some diesel generators are geared for the home while others are geared for a business environment.

Safety is another important feature of diesel generators. Many come with shutdowns for low oil pressure and automatic shutdowns. Some models also come with advanced output controlled inverter technology, which prevents overloading and under loading.

Diesel generators also come in different speeds and are either liquid-cooled, or air-cooled. Diesel generators with 1800-RPM speeds will last long and are quieter; while those with 3600 RPM will be small and lighter. Air-cooled diesel generators tend to be louder, while liquid-cooled diesel generators are quieter and more dependable.

As you can see there are many different manufacturers as well as models and features available for the buyer of a diesel generator. By carefully considering your needs and wants, you can go to diesel generator websites to complete your purchasing transaction. Or, if you would rather shop in person, you can always take a trip to your local home center or industrial tool supply company.


Diesel Generators - What You Need To Know

Shopping Frye Heath Riding Boot

Tuesday, October 18, 2011

ETQ PG30P11 3,500 Watt 7 HP 208cc 4-Cycle OHV Propane Powered Portable Generator

!: discounted ETQ PG30P11 3,500 Watt 7 HP 208cc 4-Cycle OHV Propane Powered Portable Generator save

Brand : Eastern Tools & Equipment
Rate :
Price : $489.00
Post Date : Oct 19, 2011 02:33:30
Usually ships in 24 hours



ETQ Propane - powered 3,000 - watt Generator. Long - running, clean - burning... an all - around power performer! A Generator for all jobs! Perfect for emergencies, campsites, jobsites, and more. And, because it produces such a clean and steady current, you can even use it for computers and other sensitive electronics! Produces clear sine wave output... perfect for sensitive electronics like computers; 11 1/2-hr. run time @ 50% load; Single cylinder 4-stroke 208 cc engine; 3,000-watt continuous output, 3,500-watt surge output; Accepts a 20-lb propane tank; Noise level @ 23' is 60dB; Rated current is 25 amp @ 120 volts. Max current is 29.17 amp @ 120 volts; Measures 23 x 17 x 18". Weighs 103 lbs. Order yours today! Gas and diesel-powered items once gassed or oiled, cannot be returned to us. The manufacturer will require the customer to visit a qualified service center for inspection. WARNING: Gas-powered Engines / Generators cannot be shipped to California or Canada. Please check your State, County and City laws for restrictions before ordering Gas-powered Engines / Generators. ETQ Propane-powered 3,000-watt Generator

Old Gringo Cowboy Boot Grand Sale Yamaha Upright Piano Price Cheap

Thursday, April 21, 2011

Diesel Generators: Advantages and Disadvantages

!: Diesel Generators: Advantages and Disadvantages

Are you planning to buy a diesel generator for your power supplies during black out? If the answer is "yes", then you need to know what the advantages and disadvantages of diesel generators. This generator is usually used for constant power supply within the existence of fewer moving machinery that requires less maintenance and repairs.

They are a particular device that functionally converts into diesel fuel to produce electricity. It is the two part procedure that works jointly in order to produce power supply. The diesel generator can make nonstop electricity flow with no spikes and sags. This type of generator is the cheapest electrical generation machine that allows you the best running price as compared to gasoline, natural gas generators and propane.

The following are the most necessary disadvantages and advantages of diesel fueled generators before you decide to get one.

Advantages:

1. Diesel fuel is much cheaper than some other hydro carbonic fluids. If you use diesel in power generators you can save 28-30 percent of your operating costs. The money spent on the diesel is not too high due to its ability to produce more power supply at a comparable amount of capacity.

2. The price of maintenance for diesel generators is comparatively cheaper compared to gasoline generators. In conditions of lubrication engines lubricants will also save you some money like gasoline engines.

3. In this kind of generator, the power supply is adequate. You can facilitate a 15Kw-200kw production range of diesel generators.

4. The diesel engines are also sturdier than gasoline engines and other electricity resources. Just keep up with the usual repairs so you can use it for many years to come.

5. In general, the burning up of diesel engines is lower than other generators. It also comprises for the long hours of work because it can cool down rapidly due to air cooled and water engines.

6. The diesel generators are also accessible in almost each structural type but it depends on the power requirements you're looking for. You can simply get moveable generators, portable, home diesel generators and other most prominent accessible types of diesel generator.

Disadvantages:

1. Diesel operational generators are usually used in manufacturing applications since it can emit risky amounts of harmful smoke during exhaustion. It also produces a higher smoke compared to any other fuel generator.

2. The unavoidable truth is that diesel powered generators are louder than gasoline and natural gas generators.

3. Diesel engines are not easy to begin as compared to gas engine, especially when the weather is cold. Current diesel engines apply the glow plugs and heating elements to begin the engine. The units make the engine cylinders warm, including the air that goes to the engine. Glowing plugs and heating elements are timed so that there is an interruption to start diesel engines in that cold weather.

These diesel generators are very useful at home, work sites and other places where there is a crisis in the power supply. The entire point of being able to know the advantages and disadvantages of generators depends on your budget, what's accessible, and what you need the most when power outages occur.


Diesel Generators: Advantages and Disadvantages

!: Information Electric Chain Saw Ratings !: Best Egg Poacher For Sale !: Learn How Bulk Discount Beach Towels


Twitter Facebook Flickr RSS



Français Deutsch Italiano Português
Español 日本語 한국의 中国简体。